{"doi":"10.25148/etd.fidc009685","title":"Development of a Real-Time Single-Lead Single-Beat Frequency-Independent Myocardial Infarction Detector","abstract":"The central aim of this research is the development and deployment of a novel multilayer machine learning design with unique application for the diagnosis of myocardial infarctions (MIs) from individual heartbeats of single-lead electrocardiograms (EKGs) irrespective of their sampling frequencies over a given range. To the best of our knowledge, this design is the first to attempt inter-patient myocardial infarction detection from individual heartbeats of single-lead (lead II) electrocardiograms that achieves high accuracy and near real-time diagnosis. The processing time of 300 milliseconds to a diagnosis is just at the time range in between extremely fast heartbeats of around 300 milliseconds, or 200 beats per minute. The design achieves stable performance metrics over the frequency range of 202Hz to 2.8kHz with an accuracy of 77.12%, positive predictive value (PPV) of 75.85%, and a negative predictive value (NPV) of 83.02% over the entire PTB database; 85.07%, 81.54%, 87.31% over the PTB-XL (the largest EKG database available for research) validation set, and 84.17%, 78.37%, 87.55% over the PTB-XL test set. Major design contributions and findings of this work reveal (1) a method for the realtime detection of ventricular depolarization events in the PQRST complex from 12-lead electrocardiograms using Independent Component Analysis (ICA), with a slightly different use of ICA proposed for electrocardiogram analysis and R-peak detection/localization; (2) a multilayer Long-Short Term Memory (LSTM) neural network design that identifies infarcted patients from a single heartbeat of a single-lead (lead II) electrocardiogram; (3) and integrated LSTM neural network with an algorithm that detects the R-peaks in real time for instantaneous detection of myocardial infarctions and for effective monitoring of patients under cardiac stress and/or at risk of myocardial infarction; (4) a fully integrated 12-lead real-time classifier with even higher detection metrics and a deeper neural architecture, which could serve as a near real-time monitoring tool that could gauge disease progression and evaluate benefits gained from early intervention and treatment planning; (5) a real-time frequency-independent design based on a single-lead single-beat MI detector, which is of pivotal importance to deployment as there is no standard sampling frequency for EKGs, making them span a wider frequency spectrum. vii","journal":"Florida International University Digital Commons (Florida International University)","year":2021,"id":231220,"datarank":0.0,"base_score":0.0,"endowment":0.0,"self_citation_contribution":0.0,"citation_network_contribution":0.0,"self_endowment_contribution":0.0,"citer_contribution":0.0,"corpus_percentile":null,"corpus_rank":null,"citation_count":0,"citer_count":0,"citers_with_citation_signal":0,"citers_with_endowment":0,"datacite_reuse_total":0,"is_dataset":false,"is_dataset_confidence":0.9595,"is_data_producer":false,"deposit_databanks":null,"is_oa":true,"file_count":0,"downloads":0,"has_version_chain":false,"published_date":"2021-01-01","fair_score":null,"fair_percentile":null,"algorithm_id":"datarank_citation_only_1hop_v6","ranking_scope":"data_only","authors":[{"id":562095,"name":"Harold Martin","orcid":"0000-0001-5282-4480","position":0,"is_corresponding":true}],"reference_count":74,"raw_metadata":null,"created_at":"2026-07-18T23:55:12.400773Z","pmid":null,"pmcid":null,"fwci":null,"citation_percentile":null,"influential_citations":0,"oa_status":null,"license":null,"views":0,"total_file_size_bytes":0,"version_count":0,"fair_f":null,"fair_a":null,"fair_i":null,"fair_r":null,"fair_zscore":null,"fair_rationale":null,"fair_model":null,"fair_agent_version":null,"fair_fulltext_source":null,"fair_has_llm":null,"fair_computed_at":null,"clinical_trials":[],"software_tools":[],"db_accessions":[],"linked_datasets":[],"topics":[]}