{"doi":"10.1149/05701.3229ecst","title":"Durability of Solid Oxide Electrolysis Cell and Interconnects for Steam Electrolysis","abstract":"<jats:p>Durability of a solid oxide electrolysis cell tested at -1.5A/cm<jats:sup>2</jats:sup> for high temperature steam electrolysis was investigated in the present work under stack relevant conditions. Detailed electrochemical and microstructural analyses were carried out. The results show that both the hydrogen and the oxygen electrodes degraded during the durability test. The degree of percolation loss in the active Ni-YSZ hydrogen electrode is found to decrease along the steam flow direction whereas the formation of cracks or cavities/pores within the electrolyte shows the opposite trend. The influence of sealing and interconnects on cell degradation under harsh electrolysis conditions is further discussed.</jats:p>","journal":"ECS Transactions","year":2013,"id":653602,"datarank":0.3958585994422889,"base_score":2.639057329615259,"endowment":2.639057329615259,"self_citation_contribution":0.3958585994422889,"citation_network_contribution":0.0,"self_endowment_contribution":0.3958585994422889,"citer_contribution":0.0,"corpus_percentile":null,"corpus_rank":null,"citation_count":13,"citer_count":0,"citers_with_citation_signal":0,"citers_with_endowment":0,"datacite_reuse_total":0,"is_dataset":false,"is_dataset_confidence":null,"is_data_producer":false,"deposit_databanks":null,"is_oa":false,"file_count":0,"downloads":0,"has_version_chain":false,"published_date":null,"fair_score":null,"fair_percentile":null,"algorithm_id":"datarank_citation_only_1hop_v6","ranking_scope":"data_only","authors":[{"id":588975,"name":"Ming Chen","orcid":"0000-0003-2570-0858","position":1,"is_corresponding":false},{"id":1574442,"name":"Yi-Lin Liu","orcid":null,"position":2,"is_corresponding":false},{"id":1705375,"name":"Peter Vang Hendriksen","orcid":null,"position":3,"is_corresponding":false},{"id":1705376,"name":"Mogens Mogensen","orcid":null,"position":4,"is_corresponding":false},{"id":1705374,"name":"Xiufu Sun","orcid":null,"position":0,"is_corresponding":false}],"reference_count":0,"raw_metadata":{"has_enrichment":true,"resolved":true,"title":"Durability of Solid Oxide Electrolysis Cell and Interconnects for Steam Electrolysis","abstract":"<jats:p>Durability of a solid oxide electrolysis cell tested at -1.5A/cm<jats:sup>2</jats:sup> for high temperature steam electrolysis was investigated in the present work under stack relevant conditions. Detailed electrochemical and microstructural analyses were carried out. The results show that both the hydrogen and the oxygen electrodes degraded during the durability test. The degree of percolation loss in the active Ni-YSZ hydrogen electrode is found to decrease along the steam flow direction whereas the formation of cracks or cavities/pores within the electrolyte shows the opposite trend. The influence of sealing and interconnects on cell degradation under harsh electrolysis conditions is further discussed.</jats:p>","is_dataset_classified":null,"base_score":2.639057329615259,"endowment":2.639057329615259,"datacite_reuse_total":0,"file_count":0,"downloads":0,"views":0,"has_version_chain":false,"is_dataset":false,"is_oa":false,"pmid":"19162232","pmcid":null,"openalex_id":"https://openalex.org/W2067937463","authors":[],"funders":[],"total_grants":0,"fwci":7.2787,"citation_percentile":0.97318976,"influential_citations":0,"citation_trend":[{"year":2014,"count":2},{"year":2015,"count":3},{"year":2016,"count":1},{"year":2017,"count":1},{"year":2018,"count":2},{"year":2019,"count":2},{"year":2026,"count":2}],"oa_status":"bronze","license":"https://iopscience.iop.org/info/page/text-and-data-mining","oa_locations":[{"url":"https://iopscience.iop.org/article/10.1149/05701.3229ecst/pdf","host_type":"journal"},{"url":"https://iopscience.iop.org/article/10.1149/05701.3229ecst/pdf","host_type":"publisher"},{"url":"https://iopscience.iop.org/article/10.1149/05701.3229ecst","host_type":"publisher"},{"url":"https://syndication.highwire.org/content/doi/10.1149/05701.3229ecst","host_type":"publisher"},{"url":"https://doi.org/10.1149/05701.3229ecst","host_type":"journal"},{"url":"https://orbit.dtu.dk/en/publications/c2788ce6-43c3-44a2-8845-c6ca14dd2eb6","host_type":"repository"}],"fields_of_study":["Advancements in Solid Oxide Fuel Cells","Molten salt chemistry and electrochemical processes","Fuel Cells and Related Materials"],"mesh_terms":[],"keywords":["Electrolysis","High-temperature electrolysis","Durability","Polymer electrolyte membrane electrolysis","Electrolytic cell","Materials science","Oxide","Nuclear engineering","Alkaline water electrolysis","Metallurgy","Chemistry","Engineering","Electrode","Composite material"],"sdg_mappings":[],"linked_datasets":[],"clinical_trials":[],"software_tools":[],"database_accessions":[],"source":"live","citation_network_status":"fetched"},"created_at":"2026-08-10T23:10:35.595542Z","pmid":null,"pmcid":null,"fwci":null,"citation_percentile":null,"influential_citations":0,"oa_status":null,"license":null,"views":0,"total_file_size_bytes":0,"version_count":0,"fair_f":null,"fair_a":null,"fair_i":null,"fair_r":null,"fair_zscore":null,"fair_rationale":null,"fair_model":null,"fair_agent_version":null,"fair_fulltext_source":null,"fair_has_llm":null,"fair_computed_at":null,"clinical_trials":[],"software_tools":[],"db_accessions":[],"linked_datasets":[],"topics":[]}