{"doi":"10.1111/aor.14133","title":"Effect of pulsatility on shear‐induced extensional behavior of Von Willebrand factor","abstract":"BACKGROUND: Patients with continuous flow ventricular assist devices (CF-VADs) are at high risk for non-surgical bleeding, speculated to associate with the loss of pulsatility following CF-VAD placement. It has been hypothesized that continuous shear stress causes elongation and increased enzymatic degradation of von Willebrand Factor (vWF), a key player in thrombus formation at sites of vascular damage. However, the role of loss of pulsatility on the unravelling behavior of vWF has not been widely explored. METHODS: vWF molecules were immobilized on the surface of microfluidic devices and subjected to various pulsatile flow profiles, including continuous flow and pulsatile flow of different magnitudes, dQ/dt (i.e., first derivative of flow rate) of pulsatility and pulse frequencies to mimic in vivo shear flow environments with and without CF-VAD support. VWF elongation was observed using total internal reflection fluorescence (TIRF) microscopy. Besides, the vWF level is measured from the patients' blood sample before and after CF-VAD implantation from a clinical perspective. To our knowledge, this work is the first in providing direct, visual observation of single vWF molecule extension under controlled-pulsatile shear flow. RESULTS: Unravelling of vWF (total sample size n ~ 200 molecules) is significantly reduced under pulsatile flow (p < 0.01) compared to continuous flow. An increase in the magnitude of pulsatility further reduces unravelling lengths, while lower frequency of pulsatility (20 vs. 60 pulses per min) does not have a major effect on the maximum or minimum unravelling lengths. Evaluation of CF-VAD patient blood samples (n = 13) demonstrates that vWF levels decreased by ~40% following CF-VAD placement (p < 0.01), which correlates to single-molecule observations from a clinical point of view. CONCLUSIONS: Pulsatile flow reduces unfolding of vWF compared to continuous flow and a lower pulse frequency of 20 pulses/minute yielded comparable vWF unfolding to 60 pulses/minute. These findings could shed light on non-surgical bleeding associated with the loss of pulsatility following CF-VAD placement.","journal":"Artificial Organs","year":2021,"id":188076,"datarank":0.0,"base_score":0.0,"endowment":0.0,"self_citation_contribution":0.0,"citation_network_contribution":0.0,"self_endowment_contribution":0.0,"citer_contribution":0.0,"corpus_percentile":null,"corpus_rank":null,"citation_count":17,"citer_count":0,"citers_with_citation_signal":0,"citers_with_endowment":0,"datacite_reuse_total":0,"is_dataset":false,"is_dataset_confidence":0.9544,"is_data_producer":false,"deposit_databanks":null,"is_oa":true,"file_count":0,"downloads":0,"has_version_chain":false,"published_date":"2021-01-01","fair_score":null,"fair_percentile":null,"algorithm_id":"datarank_citation_only_1hop_v6","ranking_scope":"data_only","authors":[{"id":523908,"name":"Khanh T. Nguyen","orcid":"0000-0003-1233-7527","position":1,"is_corresponding":false},{"id":748399,"name":"Esraa Ismail","orcid":"0000-0001-8020-6997","position":2,"is_corresponding":false},{"id":749028,"name":"Leslie Donoghue","orcid":null,"position":3,"is_corresponding":false},{"id":457560,"name":"Guruprasad A. Giridharan","orcid":"0000-0003-3263-9354","position":4,"is_corresponding":false},{"id":523909,"name":"Palaniappan Sethu","orcid":"0000-0002-5794-2037","position":5,"is_corresponding":false},{"id":681868,"name":"Xuanhong Cheng","orcid":"0000-0002-6331-8572","position":6,"is_corresponding":false},{"id":336439,"name":"Yi Wang","orcid":"0000-0003-4106-5698","position":0,"is_corresponding":true}],"reference_count":31,"raw_metadata":null,"created_at":"2026-07-18T23:49:05.976005Z","pmid":"34866200","pmcid":null,"fwci":null,"citation_percentile":null,"influential_citations":0,"oa_status":null,"license":null,"views":0,"total_file_size_bytes":0,"version_count":0,"fair_f":null,"fair_a":null,"fair_i":null,"fair_r":null,"fair_zscore":null,"fair_rationale":null,"fair_model":null,"fair_agent_version":null,"fair_fulltext_source":null,"fair_has_llm":null,"fair_computed_at":null,"clinical_trials":[],"software_tools":[],"db_accessions":[],"linked_datasets":[],"topics":[]}