{"doi":"10.1063/1.1287047","title":"Probe measurements of electron temperature and density in strongly magnetized plasma","abstract":"<jats:p>It was demonstrated that with increasing probe length the electron saturation current becomes more independent of the probe potential. This provides higher accuracy of measurements of the electron density and plasma potential in a strongly magnetized plasma (B&amp;gt;0.1 T). Long probes oriented parallel to the magnetic field yield better spatial resolution in the perpendicular direction. Parallel probes, however, are very sensitive to alignment errors. To avoid this problem, a cylindrical probe with a side surface coated by a thin insulating layer is proposed.</jats:p>","journal":"Review of Scientific Instruments","year":2000,"id":34769,"datarank":0.6280862825032456,"base_score":2.3978952727983707,"endowment":2.3978952727983707,"self_citation_contribution":0.3596842909197557,"citation_network_contribution":0.26840199158348993,"self_endowment_contribution":0.3596842909197557,"citer_contribution":0.26840199158348993,"corpus_percentile":null,"corpus_rank":null,"citation_count":10,"citer_count":2,"citers_with_citation_signal":2,"citers_with_endowment":2,"datacite_reuse_total":0,"is_dataset":false,"is_dataset_confidence":null,"is_data_producer":false,"deposit_databanks":null,"is_oa":false,"file_count":0,"downloads":0,"has_version_chain":false,"published_date":null,"fair_score":null,"fair_percentile":null,"algorithm_id":"datarank_citation_only_1hop_v6","ranking_scope":"data_only","authors":[{"id":179495,"name":"V. I. Demidov","orcid":null,"position":1,"is_corresponding":false},{"id":179496,"name":"K. Rypdal","orcid":null,"position":2,"is_corresponding":false},{"id":179494,"name":"S. V. Ratynskaia","orcid":null,"position":0,"is_corresponding":false}],"reference_count":0,"raw_metadata":{"has_enrichment":true,"base_score":2.3978952727983707,"endowment":2.3978952727983707,"datacite_reuse_total":0,"file_count":0,"downloads":0,"views":0,"has_version_chain":false,"is_dataset":false,"is_oa":false,"pmid":"24523987","pmcid":null,"openalex_id":"https://openalex.org/W2020059638","authors":[],"funders":[],"total_grants":0,"fwci":3.6778,"citation_percentile":0.924294,"influential_citations":0,"citation_trend":[{"year":2012,"count":1},{"year":2021,"count":1}],"oa_status":"closed","license":null,"oa_locations":[{"url":"https://pubs.aip.org/aip/rsi/article-pdf/71/9/3382/19283233/3382_1_online.pdf","host_type":"publisher"},{"url":"https://doi.org/10.1063/1.1287047","host_type":"journal"}],"fields_of_study":["Plasma Diagnostics and Applications","Laser-induced spectroscopy and plasma","Magnetic confinement fusion research","Materials Science","Physics"],"mesh_terms":[],"keywords":["Electron temperature","Plasma","Plasma diagnostics","Electron density","Magnetic field","Langmuir probe","Electron","Materials science","Perpendicular","Atomic physics","Saturation (graph theory)","Saturation current","Resolution (logic)","Plasma parameters","Physics","Voltage"],"sdg_mappings":[{"sdg_number":0,"sdg_label":"Affordable and clean energy"}],"linked_datasets":[],"clinical_trials":[],"software_tools":[],"database_accessions":[],"source":"live","citation_network_status":"fetched"},"created_at":"2026-06-09T20:06:46.255423Z","pmid":null,"pmcid":null,"fwci":null,"citation_percentile":null,"influential_citations":0,"oa_status":null,"license":null,"views":0,"total_file_size_bytes":0,"version_count":0,"fair_f":null,"fair_a":null,"fair_i":null,"fair_r":null,"fair_zscore":null,"fair_rationale":null,"fair_model":null,"fair_agent_version":null,"fair_fulltext_source":null,"fair_has_llm":null,"fair_computed_at":null,"clinical_trials":[],"software_tools":[],"db_accessions":[],"linked_datasets":[],"topics":[]}