{"doi":"10.1016/j.nic.2005.10.002","title":"Pediatric Perfusion MR Imaging Using Arterial Spin Labeling","abstract":null,"journal":"Neuroimaging Clinics of North America","year":2006,"id":672136,"datarank":0.7064295301968502,"base_score":4.709530201312334,"endowment":4.709530201312334,"self_citation_contribution":0.7064295301968502,"citation_network_contribution":0.0,"self_endowment_contribution":0.7064295301968502,"citer_contribution":0.0,"corpus_percentile":null,"corpus_rank":null,"citation_count":110,"citer_count":0,"citers_with_citation_signal":0,"citers_with_endowment":0,"datacite_reuse_total":0,"is_dataset":false,"is_dataset_confidence":null,"is_data_producer":false,"deposit_databanks":null,"is_oa":false,"file_count":0,"downloads":0,"has_version_chain":false,"published_date":null,"fair_score":null,"fair_percentile":null,"algorithm_id":"datarank_citation_only_1hop_v6","ranking_scope":"data_only","authors":[{"id":343801,"name":"Daniel J. Licht","orcid":"0000-0002-4080-843X","position":1,"is_corresponding":false},{"id":1756058,"name":"Jiongjiong Wang","orcid":null,"position":0,"is_corresponding":false}],"reference_count":0,"raw_metadata":{"has_enrichment":true,"resolved":true,"title":"Pediatric Perfusion MR Imaging Using Arterial Spin Labeling","abstract":"Cerebral blood flow (CBF, cerebral perfusion) mirrors cerebral metabolic demand and neuronal function, and therefore, is a vital parameter in the evaluation of pediatric brain injury and recovery. Until recently, measurement of CBF involved intravenous bolus injection of contrast agents or nuclear medicine methods that were technically difficult or ethically problematic in pediatrics. The development of arterial spin label (ASL) perfusion MR imaging as a noninvasive method for measuring CBF allows for the increased ability to measure this vital physiologic parameter in any age group. This article presents the technical aspects of performing ASL perfusion MR imaging in pediatrics, and discusses its current use in clinical studies and its potential for influencing important management strategies in specific disease entities.","is_dataset_classified":null,"base_score":4.709530201312334,"endowment":4.709530201312334,"datacite_reuse_total":0,"file_count":0,"downloads":0,"views":0,"has_version_chain":false,"is_dataset":false,"is_oa":false,"pmid":"16543090","pmcid":null,"openalex_id":"https://openalex.org/W2082135003","authors":[],"funders":[{"funder_name":"NIMH NIH HHS","grant_id":"R21 MH072576","title":null},{"funder_name":"NINDS NIH HHS","grant_id":"NS052380","title":null},{"funder_name":"NICHD NIH HHS","grant_id":"HD049893","title":null}],"total_grants":3,"fwci":4.0854,"citation_percentile":0.93463754,"influential_citations":0,"citation_trend":[{"year":2012,"count":5},{"year":2013,"count":12},{"year":2014,"count":6},{"year":2015,"count":7},{"year":2016,"count":11},{"year":2017,"count":4},{"year":2018,"count":4},{"year":2019,"count":7},{"year":2020,"count":3},{"year":2021,"count":6},{"year":2022,"count":2},{"year":2023,"count":1},{"year":2024,"count":2},{"year":2025,"count":2}],"oa_status":"closed","license":"https://www.elsevier.com/tdm/userlicense/1.0/","oa_locations":[{"url":"https://api.elsevier.com/content/article/PII:S1052514905001103?httpAccept=text/xml","host_type":"publisher"},{"url":"https://api.elsevier.com/content/article/PII:S1052514905001103?httpAccept=text/plain","host_type":"publisher"},{"url":"https://doi.org/10.1016/j.nic.2005.10.002","host_type":"journal"},{"url":"https://pubmed.ncbi.nlm.nih.gov/16543090","host_type":"repository"}],"fields_of_study":["Advanced MRI Techniques and Applications","Neonatal and fetal brain pathology","Atomic and Subatomic Physics Research","Anemia, Sickle Cell","Brain Diseases","Cerebrovascular Circulation","Child","Heart Defects, Congenital","Humans","Magnetic Resonance Angiography"],"mesh_terms":["Anemia, Sickle Cell","Brain Diseases","Cerebrovascular Circulation","Child","Heart Defects, Congenital","Humans","Magnetic Resonance Angiography"],"keywords":["Medicine","Cerebral blood flow","Perfusion","Perfusion scanning","Arterial spin labeling","Cerebral perfusion pressure","Neuroimaging","Brain function","Bolus (digestion)","Magnetic resonance imaging","Radiology","Cardiology","Internal medicine","Neuroscience"],"sdg_mappings":[{"sdg_number":0,"sdg_label":"Good health and well-being"}],"linked_datasets":[],"clinical_trials":[],"software_tools":[],"database_accessions":[],"source":"live","citation_network_status":"fetched"},"created_at":"2026-08-16T06:43:53.562853Z","pmid":null,"pmcid":null,"fwci":null,"citation_percentile":null,"influential_citations":0,"oa_status":null,"license":null,"views":0,"total_file_size_bytes":0,"version_count":0,"fair_f":null,"fair_a":null,"fair_i":null,"fair_r":null,"fair_zscore":null,"fair_rationale":null,"fair_model":null,"fair_agent_version":null,"fair_fulltext_source":null,"fair_has_llm":null,"fair_computed_at":null,"clinical_trials":[],"software_tools":[],"db_accessions":[],"linked_datasets":[],"topics":[]}